Peltier Chambers from Kambic, the quiet chambers are manufactured in two standard chamber sizes with maximum operating temperature of 55°C. If required, this range also provides a foundation upon which a wide range of custom modifications can be added.
The stability chambers are for environmental simulation, material testing and stability testing. The peltier system means they are quiet, space-saving, environmentally friendly and also economical. The innovative Peltier technology in the Kambic peltier climatic chamber provide stable and precise long-term tests. The temperature control from +8 ºC to +55 ºC, as well as the active humidification and dehumidification from 10% to 98% rh, are optimally tuned to the requirements of stability analysis.
Generally, stability tests are performed at a temperature close to the ambient temperature. With the Kambic peltier chamber, the impressive economy of the heating and cooling concept with Peltier elements can be seen. Over the course of a test run lasting several months, energy savings of up to 90 % can be achieved. Because it runs so quietly, the constant climate chamber is ideal not only for environment simulation and long-term material tests, but also for breeding insects and reptiles.
|
PKK-50 |
PKK-125 |
|
||
External dimensions |
570 x 800 x 660 |
500 x 500 x 500 |
Internal dimensions |
400 x 400 x 360 |
670 x 1135 x 755 |
Volume (L) |
57 |
125 |
Temperature range (°C) |
+8 ...+55 |
+10...+50°C |
Temperature display resolution (°C) |
0.001 |
0.001 |
Temperature set resolution (°C) |
0.1 |
0.1 |
Temperature Stability |
±0.06 @ 15 °C, 75%Rh ±0.04 @ 20 °C, 60%Rh ±0.03 @ 30 °C, 65%Rh ±0.06 @ 50 °C, 75%Rh ±0.12 @ 50 °C, 15%Rh |
±0.08 @ 15 °C, 75%Rh ±0.05 @ 20 °C, 60%Rh ±0.05 @ 30 °C, 65%Rh ±0.10 @ 50 °C, 75%Rh ±0.10 @ 50 °C, 15%Rh |
Temperature uniformity (°C) |
±0.25 @ 15 °C, 75%Rh ±0.25 @ 20 °C, 60%Rh ±0.48 @ 30 °C, 65%Rh ±0.58 @ 50 °C, 75%Rh ±1.30 @ 50 °C, 15%Rh |
±0.30 @ 15 °C, 75%Rh ±0.25 @ 20 °C, 60%Rh ±0.50 @ 30 °C, 65%Rh ±0.60 @ 50 °C, 75%Rh ±1.30 @ 50 °C, 15%Rh |
Relative humidity range (%) |
10...98 |
10...98 |
Relative humidity display resolution (%) |
0.1 |
0.1 |
Relative humidity set resolution (%) |
0.1 |
0.1 |
Relative humidity stability (%) |
±0.3 @ 15 °C, 75%Rh ±0.3 @ 20 °C, 60%Rh ±0.3 @ 30 °C, 65%Rh ±0.3 @ 50 °C, 75%Rh ±0.3 @ 50 °C, 15%Rh |
±0.3 @ 15 °C, 75%Rh ±0.3 @ 20 °C, 60%Rh ±0.3 @ 30 °C, 65%Rh ±0.3 @ 50 °C, 75%Rh ±0.3 @ 50 °C, 15%Rh |
Temperature control |
PID |
PID |
Relative humidity control |
Dew point humidity control / dry air purge for extended |
Dew point humidity control / dry air purge for extended |
Power supply |
230 V 50/60 Hz |
230 V 50/60 Hz |
Wattage (W) |
500 |
500 |
Interface |
RS 232 |
RS 232 |
Shelve |
1 (max 4) |
1 (max 6) |
Shelve capacity (kg) |
15 |
20 |
Max capacity (kg) |
30 |
50 |
Access port (mm) |
Ø 40 standard, |
Ø 40 standard, |
Noise (dBA) @ 1 m distance |
<50 |
<50 |
Weight (kg) |
36 |
75 |