New Product Announcement
 
The Fluke Calibration 5500A Series Multiproduct Calibrators (5560A, 5550A, 5540A) allow you to calibrate the widest range of test tools with a single high accuracy instrument, including 6.5 digit multimeters and 5.5 digit multimeters.
Fluke Calibration 5560A High-Performance Multi-Product Calibrator
Fluke Calibration 5550A Performance Multi-Product Calibrator
Fluke Calibration 5540A Multi-Product Calibrator
| For.... (target market) | Third party calibration laboratories On-site calibration laboratories | 
| Product is... | Multi-product calibration of handheld DMMs, bench DMMs, oscilloscopes, process calibrators, temperature readouts, handheld ICR meters and more | 
| That... (differentiated value proposition) | Provides the widest range of electrical workload coverage in its class | 
| That’s because..... (reason to believe) | 
 | 
Technical Specifications
| Function | Range | 
| Direct volts | 0 V to ± 1020 V | 
| Direct current | 0 to ± 30.2 A | 
| Alternating volts | 1 mV to 1020 V 3 Hz to 500 kHz | 
| Alternating current | 10 μA to 30.2 A 3 Hz to 30 kHz | 
| Volt/hertz | 1000 V at 10 kHz/330 V at 100 kHz | 
| Waveforms | Sine Wave, Square Wave, Pulse/Duty Cycle | 
| Resistance variable | 0 Ω to 1200 MΩ | 
| Capacitance variable | 200 pF to 120 mF | 
| Inductance variable | 13 μH to 120 H (not on 5540A) | 
| Power (dual output – phantom loads) | 30.9 kW (not on 5540A) | 
| Phase lock | Yes | 
| Phase control | 0.01° | 
| Frequency uncertainty | <2.5 ppm | 
| Temperature standard | <ITS-90, IPTS-68 | 
| Resistance temperature detectors (RTDs) output | Pt100 385, Pt100 395, Pt100 3916, Pt200 385, Pt500 385, Pt1000 385, Ni120, Cu10 Compensation: off, 2-wire, 4-wire | 
| External frequency reference 10 MHz | Yes | 
| Thermocouples (source and measure) External or internal CJR | A1 (BP,A), B, C, D, E, G, J, K, L, N, R, S, T, U, XK, 10 μV/°C, 1 mV/°C | 
| Scope calibrator | SC600 – with levelled sine up to 600 MHz SC1100 – with levelled sine up to 1100 MHz SC2100 – with levelled sine up to 2100 MHz | 
| Interfaces / Remote commands | USB 2.0, Ethernet Telnet, RS-232 and GPIB | 
| 52120A Amplifier current capability | Current capability up to 120 A | 
Pricing
| Model | Oracle Number | Description | Region Sold in | List Price EUR | Origin | 
| 5560A | 5128168 | High-Performance Multi-Product Calibrator | Global | 69,900 | US | 
| 5550A | 5215654 | Performance Multi-Product Calibrator | Global | 69,900 | US | 
| 5540A | 5215687 | Multi-Product Calibrator | Global | 26,000 | US | 
| 55XXA/LEADS | 5128204 | Test Lead Set For 55xxa W/Lead Cas | Global | 1,680 | US | 
| 55XXA/COIL10 | 5128219 | 1, 2 and 10-Turn Current Coil, Includes an Accredited 17025 Calibration Certificate Traceable to International Standards with Data | Global | 1,160 | UK | 
| 55XXA/PORTKIT | 5128243 | 5560A Portability it for On-Site Calibrations | Global | 1,735 | US | 
| 55XX/CASE | 5128255 | Extra Case, 5560A, 5550A and 5540A Include Hard Case | Global | 1,835 | US | 
| 55XXA/DMMCAL | 5128237 | DMM AUTOCAL Adapter | Global | 1,645 | SIN | 
| Item No | Item description | Model | Price EUR | 
| 5499115 | 1 YR GCP,5540A STANDARD, MULTI-PRODUCT CALIBRATOR ACRCAL | GCP5540A | 3,100 | 
| 5499144 | 1 YR SCP,5540A STANDARD, MULTI-PRODUCT CALIBRATOR ACRCAL | SCP5540A-ACR | 1,600 | 
| 5499126 | 1 YR GCP,5550A PERFORMANCE, MULTI-PRODUCT CALIBRATOR ACRCAL | GCP5550A-ACR | 4,500 | 
| 5499159 | 1 YR SCP,5550A PERFORMANCE, MULTI-PRODUCT CALIBRATOR ACRCAL | SCP5550A-ACR | 2,900 | 
| 5499132 | 1 YR GCP, 5560A HIGH PERFORMANCE, MULTI-PRODUCT CALIBRATOR ACRCAL | GCP5560A-ACR | 5,900 | 
| 5499167 | 1 YR SCP, 5560A HIGH PERFORMANCE, MULTI-PRODUCT CALIBRATOR ACRCAL | SCP5560A-ACR | 3900 | 
Ask for a quote
For a quote please contact our sales department:
January 15, 2023




 
					